Mrs Jones wants comfort. The builder wants numbers. The QS wants square metres. The architect wants the clause. Stickman made five doors so nobody has to read the wrong sermon.

I'm a Homeowner
My bedroom is a slow cooker, my tiles are rude, and Eskom is becoming a dependant. Take me on the journey.

I'm an Architect
R-values, compliance routes, specs, datasheets, and the sentence that keeps council calm.

I'm a Builder
Give me thickness, area, fixing method, and nobody gets sent a 14-page brochure.

I'm a Quantity Surveyor
I came for square metres, wastage, rates, and the emotional safety of a clean spreadsheet.
Your roof is not a braai.
Your bedroom is not the side dish.
A guided tour through Mrs Jones' house, where Stickman points at the naughty bits and nobody needs a hard hat. A few quick questions, then the right fix. No lecture, no clipboard, no "just trust me".
Diagnose My House
Tap whichever part of the house is making your life difficult. Stickman will explain why, then point you at the fix.
Things Your Roof Did Not Want Mentioned in Public
Stickman Stocks Three. Here They Are.
| ISOboard | Lambdaboard | Summit XPS | |
|---|---|---|---|
| What it is | A solid board, the same all the way through | A board with a bonded skin on both faces | A solid board, the same all the way through |
| How thick it comes | 25mm to 80mm | 25mm to 100mm | 30mm to 100mm |
| How well it insulates | 50mm gives R1.91 | 50mm gives R2.08 | 50mm gives R1.67 |
| Board size | 600mm wide, 1.8m to 8m long | 1220mm wide, cut to your length up to 12m | 600mm wide, 1.8m to 8m long |
| If it gets wet | Takes on 0.87% water by volume | Takes on under 1% by mass, and keeps its R-value | Takes on under 0.5% by volume |
| If it meets a flame | Softens and pulls away from the heat. Classified to SANS 428. | Does not melt or drip — it is a thermoset. Class A to external flame. | Shrinks away from the heat. Also classified to SANS 428. |
| Can you leave it on show? | Yes — bevelled edge, paint it or leave it white | Yes — three factory colours, no painting needed | Yes — smooth or pine-groove finishes |
| Painting it | Water-based paint only, on all three. Solvent-based paint damages the board. Two coats of matt acrylic or PVA is the standard. | ||
| Downlights | LED or energy-saver only, and nothing that runs hotter than 70°C against the board. Transformers sit off the board with a 150mm air gap. Tell your installer before they start. | ||
| Paperwork it arrives with | Five Agrément SA certificates, one per application | Fire and toxicity test results — no current Agrément SA certificate | Fire test report — no Agrément SA certificate |
+ WHERE THESE FACTS COME FROM
Things to Know Before the Bakkie Reverses In
Questions Mrs Jones Asked Before She Let Stickman Near the Ceiling
Right. Let's Stop the House Behaving Like a Weather Experiment.
People say insulation is boring. That is the product — nothing happens, and you pay for nothing to happen. Send us the room, roof, wall, or floor drama and Stickman will turn "the ceiling thingy" into a proper quote before Mrs Jones orders another fan.
Skip the Story.
Get to the Numbers.
Four applications. Three boards. Direct links. Stickman knows you didn't come here for a journey.
Stickman note: a helpful guide to SANS 10400-XA, not a compliance sign-off — check the standard, the drawings and the competent person's assessment.
Find Your Zone, Get Your Numbers
Three Boards on the Shelf
| ISOboard | Lambdaboard | Summit XPS | |
|---|---|---|---|
| Material | XPS, 100% closed cell, unfaced | PIR thermoset, faced both sides | XPS, closed cell, unfaced |
| Thermal conductivity | k = 0.026 W/m·K | k = 0.024 W/m·K | k = 0.03 W/m·K |
| Thicknesses | 25 / 30 / 40 / 50 / 60 / 70 / 80mm 90mm and 100mm as doubled boards |
25 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100mm 5mm steps special order, 14 working days |
30 / 40 / 50mm single 60 / 80 / 100mm as doubled boards 70mm and 90mm on special order — ask us to price no 25mm |
| Board width | 600mm (±2mm) | 1220mm | 600mm |
| Lengths | 1.8m – 8.0m 1.8 / 2.4 / 2.7 / 3.0 / 3.3 / 3.6 / 4.0 / 4.2 / 4.8 / 5.4 / 6.0 / 6.6 / 7.2 / 8.0m |
Cut to length, 2m – 12m Stock: 5.4m / 6m / 8m 10% cutting charge under 2m |
1.8m – 8.0m 1.8 / 2.1 / 2.4 / 2.7 / 3.0 / 3.3 / 3.6 / 4.0 / 4.2 / 4.8 / 5.4 / 6.0 / 6.6 / 7.2 / 8.0m |
| Cutting on site | Sharp knife, hacksaw, fine-tooth saw or hot wire | Handsaw or fine-tooth blade wear a dust mask — PIR dust irritates |
Handsaw or fine-tooth blade wipe with dishwashing liquid first to kill static |
| Ceiling batten spacing | Max 700mm centres | 900mm centres | Max 700mm centres |
| Fixing | Adhesive at 200mm + concealed clips; perimeter screws at 300mm | Drywall fasteners through the board into battens, or concealed clip | Adhesive 5ml drops at 200mm + 3 clips per m²; perimeter screws at 300mm |
| Max purlin span, unsupported | 30mm: 1400mm galv / 1200mm painted 40mm+: 1600mm / 1500mm |
25mm: 1300mm · 30mm: 1400mm · 40mm: 1800mm 50–60mm: 2000mm · 70–90mm: 2200mm |
30mm: 1400mm galv / 1200mm painted 40mm+: 1600mm / 1500mm |
| Density | 32 – 36 kg/m³ | 40 kg/m³ | 35 – 37 kg/m³ |
| Compressive strength | 160 – 310 kPa | Available on request | 310 – 360 kPa |
| Fire classification | SANS 428 B/B1/2/H&V SANS 53501-1 B-s1,d0 |
SANS 53501-1 D-s3,d0 ASTM E108 Class A external SANS 428 report lapsed — ask for current position |
SANS 428 B/B1/2/H&V SANS 53501-1 B-s1,d1 |
| Certification | Agrément SA × 5, one per application | Test reports; NES 713 confined spaces no Agrément SA certificate |
Fire test report; no Agrément SA certificate |
| Finish options | 25–50mm T&G · 60–80mm shiplap · IsoPine grooved | Coated glass facer × 3 colours · aluminium foil facer Decoboard 30mm: rounded edge, 600mm wide |
Smooth or pine T&G · bevel · straight |
| Lead time | Ex stock where available; confirm per order | 2–3 working days ex stock 14 working days if not in stock |
Ex stock where available; confirm per order |
| Our planning rule | We plan 14 working days from 60mm upward on all three where the thickness is not in stock. That is our own scheduling default rather than a supplier guarantee — ask us to confirm against current stock before you commit a date. | ||
Things That Catch People Out
| Detail | What it means on site |
|---|---|
| Slipsheet under roof sheeting | Galvanised and fibre-cement sheets need no slipsheet. Chromadek cladding does — a slipsheet goes between the sheeting and the board. On pierced-fix systems: felt-fibre for residential and commercial, kraft paper for industrial. Get this wrong and the certificate detail is not met. |
| Curved roofs | ISOboard follows a curve, but for radii over 600mm the boards must be pre-grooved to half their thickness at 75mm centres. That is a factory instruction, not a site one — tell us the radius when you order. Summit states it can follow a 5m radius curve. |
| Extending an unsupported span | Where purlin spacing exceeds the span limit, T- or H-sections carry the board. The limits change with thickness — Lambdaboard publishes: 25mm — no section under 1300, T 1400–1800, H 1900–2800 30mm — no section under 1400, T 1500–1800, H 1900–2800 40mm — no section under 1800, T 1900–2100, H 2200–2800 50 and 60mm — no section under 2000, T at 2100, H 2200–2800 70, 80 and 90mm — no section under 2200, T 2300–2500, no H section Sections are 6m lengths, colour matched to White Mineral, made in 30–60mm only. There is no H-section above 60mm, so the thicker boards cannot be carried beyond 2500mm. On ISOboard and Summit, use square-edged board with the tongue removed where sections are fitted. |
| Facing materials void the certificate | ISOboard's Agrément certification excludes use with any other facing material — combustible or non-combustible — unless a satisfactory fire test report exists for that specific combination. Laminating a vinyl facing or slipsheet to the board raises the fire risk and needs the sales office consulted first. Do not assume a certificate travels with a build-up it was never tested in. |
| Coastal condensation | Condensation is unlikely on the underside of the ceiling, but warm humid air permeates the joints and condenses on cold roof sheeting above, then drips and stains. A continuous bead of sealant in the grooved edge during installation largely prevents it. In the Southern Coastal Condensation Problem Area, roof ventilation is required per the certificate supplement. High humidity also risks corrosion on untreated inner faces of sheeting. |
| Repairing damage | Dents and knocks fill with Polyfilla mixed with Alcolin Permabond diluted 1:3, or a compatible non-brittle polymer filler. A badly damaged board is individually replaceable — remove the tongue of the replacement board where needed rather than pulling the run apart. Boards can be washed by hand or high-pressure jet with a compatible detergent. |
| Retrofitting under an existing ceiling | Board can go up under an existing ceiling or a concrete soffit — battens fix below the soffit and the board fixes to those. For industrial retrofits under roof sheeting, brandering runs at 600mm intervals from ridge to eave with board running portal frame to portal frame, and short pieces up to 2400mm are used. Roughly 3 clips per m² with glue rows about 600mm apart. |
| Wind-exposed areas | Under eaves, on verandas and in high wind-load areas: either halve the brandering spacing or double the fixing points. Both suppliers of XPS state this. It is the single most common cause of a ceiling coming loose. |
| Order size changes the rate | Pricing steps at 500m², and the threshold is judged on the total order area — summed across every room, thickness and board length. How the order is split makes no difference. Reaching 500m² applies the better rate to the whole order, so it is worth telling us the full project rather than phoning it in room by room. |
+ SOURCES FOR THIS SECTION
How Each Board Is Measured and Sold
| ISOboard | Lambdaboard | Summit XPS | |
|---|---|---|---|
| Sold by | Per board length | Per square metre | Per board length |
| Why | Fixed stock lengths | Cut to your length | Fixed stock lengths |
| Board width | 600mm | 1220mm | 600mm |
| Coverage per board | length × 0.6m | as ordered | length × 0.6m |
| A 6m board covers | 3.6m² | 7.32m² at 6m | 3.6m² |
| Cutting charge | None stated — cut-to-length available at distribution centres | 10% below 2m | None stated |
| Delivery in the price | Not stated — confirm per order | Included in JHB and Pretoria up to 6m lengths. Below 300m² delivery is charged, plus a 10% cutting premium. The supplier's own conditions 3 and 4 disagree on this threshold — confirm before quoting. |
Included — delivery to store |
| Waste | Excluded from all three price lists. Allow for it separately in the rate. | ||
What Moves the Rate
| Driver | Effect on the rate |
|---|---|
| Total order area | Pricing steps at 500m². Qualification is on the total order — summed across every room, thickness and board length. How the order is split makes no difference, and once the total reaches 500m² the better rate applies to the whole order. Price the project, not the room. |
| Energy zone | Zone sets the R-value, R-value sets the thickness, thickness sets the rate. A multi-site tender spanning two zones cannot carry one blended rate — Zone 5H needs materially less than the rest. |
| Application | Maximum thickness differs by application, so a variation from ceiling to roof is not a like-for-like swap. Nail-up caps at 50mm on the XPS boards and 40mm on Lambdaboard; over purlin and inverted roof reach 100mm. |
| Colour and finish | Never a separate add-on. The colour is priced into the board rate before markup, so a coloured board carries one rate — do not add a finishing line item on top. ISOboard offers painted categories; Lambdaboard's Gun Metal Grey and Obsidian Black carry a flat uplift over White Mineral. |
| Special-order thickness | Lambdaboard's 5mm intermediate sizes (35, 45, 55mm and so on) are special order at 14 working days. Summit's 70mm and 90mm are special order with no standard rate. Both need pricing on enquiry rather than interpolation. |
| Lead time from 60mm | All three carry 14 working days on 60mm and thicker if not in stock. That is a programme risk, not a rate change, but it belongs in the preliminaries discussion. |
| Concealed applications | Where the board will never be seen — cavity walls, under surface bed, inverted roof — damaged and seconds stock is available at a materially lower rate. First come, first serve and never reserved, so it suits a contingency saving rather than a tendered rate. |
| Volume and cash | ISOboard runs a separate volume bracket structure priced per cubic metre for 100% cash-upfront orders, starting at 50m³. Summit applies a volume discount above 500m². Worth asking about on anything large before the rate is fixed. |
Building the BOQ Line
| Item | Position |
|---|---|
| Unit | Square metres. Even where a board is bought per length, the BOQ line is almost always m² — convert at length × 0.6m for the 600mm boards. |
| Description must carry | Material (XPS or PIR), thickness in mm, the assembly R-value required, the application, and the fixing basis. Naming a brand narrows the tender; specifying performance keeps it open. |
| Careful with | "Agrément SA certified" in a description restricts the line to ISOboard alone — it is the only one of the three holding certificates. Include it only if you mean to. |
| Wastage | 5–10% is the standard allowance for cuts and offsets. Push it higher on irregular roof shapes and layouts with many penetrations. Cut-to-length ordering reduces it. |
| Not in the supplier rate | Waste, installation labour, and adhesive, clips and fixings — on all three. Delivery varies: Summit includes delivery to store in its list price; Lambdaboard includes JHB and Pretoria up to 6m lengths but charges below 300m² along with a 10% cutting premium; ISOboard delivery is confirmed per order. Price these separately or the line under-recovers. |
| Accessories to allow for | Concealed clips at roughly 3 per m², adhesive at roughly 30m² per litre, perimeter drywall screws, and T- or H-sections where purlin spacing exceeds the board's unsupported span. |
| Reconciliation | Confirm quantities actually installed rather than originally ordered. Insulation is usually one of the more stable line items, but returns of unused, undamaged stock are discussed case by case rather than credited automatically. |
+ SOURCES FOR THESE SECTIONS
Questions From the Site
The Google Question Corner
Need a Bulk Quote or Trade Pricing?
Send through your project specs and quantities — we'll come back with proper trade numbers fast.
Spec It Properly.
Keep the Builder Honest.
SANS 10400-XA compliance routes, R-value tables by zone and by thickness, application limits, full material properties for all three stocked systems, and datasheets — without Stickman losing his sense of humour entirely.
Stickman note: this page is a helpful guide to SANS 10400-XA:2026, but final compliance must be checked against the official standard, the project drawings, the selected compliance route, and the competent person's project-specific assessment.
Find Your Zone, Get Your Target
Three Routes to Compliance Deemed-to-Satisfy, or either of the two Rational Design routes under Regulation XA3. Choose deliberately. Comparison table
| Aspect | Deemed-to-Satisfy (DTS) | Rational Design — Standard Comparison | Rational Design — Reference Building |
|---|---|---|---|
| Regulation clause | XA3(a) | XA3(b) | XA3(c) |
| Approach | Follow the prescriptive R-value tables in SANS 10400-XA directly by zone and element type. | A competent person demonstrates the building's energy usage is equivalent to or better than what the standard's own requirements would achieve. | Certified thermal simulation software compares the actual design's theoretical energy performance against a notional reference building built to DTS minimums. |
| Speed of approval | Fast — building control officers recognise the tables immediately. | Slower — requires a submitted rational design report and sign-off. | Slower still — requires certified software output and competent person certification. |
| Flexibility | Conservative and fixed; no allowance for unusual envelope designs, glazing ratios, or thermal mass strategies. | Allows trade-offs against the standard's own benchmarks — e.g. thinner insulation offset by better glazing or orientation. | Most flexible — whole-building simulation can balance glazing, shading, fabric, and hot water against each other freely. |
| Typical cost outcome | Often conservative, sometimes over-specifying thickness "to be safe". | Can reduce insulation cost on larger projects by avoiding over-specification. | Often the biggest potential saving on glazing-heavy or architecturally complex designs, offset by consultant fees. |
| Who signs off | Self-certified against the published tables, building control verifies. | A competent person produces and stamps the rational design report. | A competent person certifies the building's theoretical energy usage and demand against the reference building, using certified thermal calculation software. |
| Best suited to | Standard residential and small commercial projects with conventional envelopes. | Projects with a specific trade-off in mind that the tables don't accommodate. | Large commercial, glazing-heavy, or architecturally ambitious projects where the fee is justified by potential savings. |
+ SOURCES FOR THIS SECTION
SANS 10400-XA:2026 R-Value Requirements
| Element | Zone 1 | Zone 2 | Zone 3 | Zone 4 | Zone 5 | Zone 5H | Zone 6/7 |
|---|---|---|---|---|---|---|---|
| Roof (R-value) | 3.7 | 3.7 | 3.7 | 3.7 | 3.7 | 2.7 | 3.7 |
| Roof (~mm, ISOboard) | ~100mm | ~100mm | ~100mm | ~100mm | ~100mm | ~70mm | ~100mm |
| Floor, underfloor heating only | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Wall (R-value, ≥270 kg/m²) | 0.6 | 0.6 | 0.4 | 0.6 | 0.4 | 0.4 | 0.6 |
| Wall deemed-to-satisfy | 50mm cavity wall | 50mm cavity wall | Collar jointed wall | 50mm cavity wall | Collar jointed wall | Collar jointed wall | 50mm cavity wall |
Scope, Exclusions and the Small Print
| Issue | Position |
|---|---|
| Occupancy classes inside Regulation XA | Minimum energy requirements apply to A1–A4, C1–C2, E1–E4, F1–F3, G1 and H1–H5. Assembly, institutional, educational, commercial-retail, health and residential occupancies, broadly. |
| Occupancy classes outside it | B1–B3, D1–D4 and J1–J4 fall outside the scope of Regulation XA — high-risk commercial, industrial and plant, and storage or parking. No minimum energy requirement applies to those uses beyond what the owner or tenant wants. Worth establishing before you spend a fee on a rational design for a warehouse. |
| Single layer or combination | The added R-value required for a roof may be achieved by a single layer of insulation or by a combination of compatible insulation systems. You are not obliged to reach the figure with one product. Note the exception below on Lambdaboard. |
| Double-layering Lambdaboard | Rigifoam states that double-layer boards compromise fire compliance and double the installation labour. Where ISOboard and Summit offer doubled boards as a route to greater thickness, Lambdaboard does not — specify a single thicker board. |
| Certification and facing materials | ISOboard's Agrément certification excludes use in combination with any other facing material, combustible or not, without a satisfactory fire test report on that combination. A laminated vinyl facing or a bonded slipsheet raises the fire risk and voids the certified position. Do not carry a certificate across into an untested build-up. |
| Roof table applicable | Added R-value for roofs is read from Table 8 for metal sheeting roof assemblies and Table 9 for clay tile roof assemblies. Confirm which applies before reading a figure off the wrong table. |
| Southern Coastal Condensation Problem Area | Roof ventilation is required in this area per the supplement to the Agrément certificates. Warm humid air permeating board joints condenses on cold roof sheeting; a continuous sealant bead in the grooved edge at installation greatly reduces it. High humidity also carries a corrosion risk to untreated inner faces of sheeting. |
| Application-specific certification | ISOboard's five certificates each cover one application — 2006/323 nail-up ceilings, 2001/287 over purlin, 2010/382 over rafter and truss, 2000/277 inverted roof, 2000/276 cavity wall. Under floor slab, under soffit, retrofit and cornice profiles are listed without certificates. Certification validity is reviewed every three years. |
| Over rafter and truss thickness limit | Agrément 2010/382 limits this application to a maximum 40mm board, excludes nails as a fixing, and permits no other facing material. The 2024 counter-purlin brochure presents a different method reaching 60mm — the two do not agree, so confirm which basis the project is using. |
| Repairs and replacement | Damaged boards are individually replaceable, with the tongue of the replacement removed where needed. Fillers: Polyfilla with Alcolin Permabond diluted 1:3, or a compatible non-brittle polymer filler. Re-decoration follows plasterboard practice. |
+ SOURCES FOR THIS SECTION
Material Properties at a Glance
| Property | ISOboard | Lambdaboard | Summit XPS |
|---|---|---|---|
| Material | XPS, extruded, 100% closed cell, unfaced | PIR thermoset, faced both sides | XPS, extruded, closed cell, unfaced |
| Thermal conductivity (k) | 0.026 W/m·K declared tested 0.02624, SANS 8301 |
0.024 W/m·K aged, ASTM C518 at 22°C mean |
0.03 W/m·K ISO 8302 |
| R-value basis | Tested k, SANS 8301 heat flow meter | LTTR — measured aged, guaranteed for the life of the building | Calculated on declared k; aged basis not stated |
| Thickness range | 25 – 80mm 90 / 100mm as doubled boards |
25 – 100mm 5mm steps special order |
30 / 40 / 50mm single 60 / 80 / 100mm doubled; 70 / 90mm special order; no 25mm |
| Standard width | 600mm (±2mm) | 1220mm | 600mm |
| Available lengths | 1.8 – 8.0m 1.8 / 2.4 / 2.7 / 3.0 / 3.3 / 3.6 / 4.0 / 4.2 / 4.8 / 5.4 / 6.0 / 6.6 / 7.2 / 8.0m |
2 – 12m cut to length; stock 5.4 / 6 / 8m | 1.8 – 8.0m 15 stock lengths, 1.8m upward |
| Density | 32 – 36 kg/m³ declared tested 37.2 kg/m³ |
40 kg/m³ (ASTM D1622) core 34 kg/m³ |
35 – 37 kg/m³ (±4%) |
| Compressive strength | 160 – 310 kPa, rises with thickness | Available on request | 310 – 360 kPa |
| Water absorption | 0.87% by volume (ISO 2896) | < 1% by mass (SANS 1381-1) | < 0.5% by volume (ISO 2896) |
| Dimensional stability | < 0.86% all three axes | < 1% (ASTM 2126) | < 1% (EN 1604) |
| Vapour permeability | Not published | Not published | 369 g/m² (ISO 1663) |
| Performance when wet | Retains about 80% of thermal resistance after 1000 days wetting (CRREL research on XPS) | Does not lose R-value when exposed to water; LTTR guaranteed for the life of the building | Closed cell — long-term performance from inherent moisture resistance |
| Long-term field data | Boards in service up to 20 years average k = 0.028 W/m·K | LTTR basis — values already measured aged | Not published |
| Service temperature | −30°C to +60°C | −30°C to +120°C datasheet states −60°C to +120°C |
Not published — softens above 70°C |
| Fire classification | SANS 428 B/B1/2/H&V (25 – 80mm) SANS 53501-1 B-s1,d0 |
SANS 53501-1 D-s3,d0 ASTM E108 Class A external no current SANS 428 report |
SANS 428 B/B1/2/H&V SANS 53501-1 B-s1,d1 |
| Behaviour in fire | Thermoplastic — softens and retracts from the heat source, no flaming droplets | Thermoset — does not melt, drip or spread flame; will not affect sprinkler performance | Thermoplastic — shrinks away, no flaming droplets or flame spread |
| Where it may not be used | None of the three may be used where the regulations prescribe non-combustible materials — hotels and hospitals are the usual examples. All are classified combustible. | ||
| Combustion products | Not published | CO, CO2, HCN and NOx under sustained flame (per SDS) | Not published |
| Toxicity | Not published | Approved for confined spaces (NES 713) | Not published |
| Biological | Rot-proof; no food value to vermin; will not support mould or fungal growth | Mildew and bacteria resistant | Closed cell; cornices pest-resistant |
| Chemical resistance | Damaged by solvents and VOCs; degraded by UV if left unpainted | Resists alkalis, solvents, paints and adhesives | Damaged by ANY solvent or solvent-based product; UV exposure requires paint |
| Painting | Two coats water-based matt acrylic or PVA. Solvent-based paints must not be used. | One to two coats acrylic on Decoboard; factory facing elsewhere | Two coats water-based matt PVA over an acrylic filler coat. Water-based only. |
| Facings | None — unfaced, white | Coated glass facer, three colours; aluminium foil facer option for cavity walls and under roof covering | None — unfaced |
| Edge profiles | 25–50mm tongue & groove; 60–80mm shiplap IsoPine grooved finish optional; shiplap for inverted roof |
Square edge; Decoboard 30mm is rounded-edge T&G and is 600mm wide, not 1220mm | Smooth or pine T&G, bevel T&G, straight |
| Environmental | Zero ODP (R134a / R152a blowing agent) EcoStandard SA three-star label expired Dec 2023 |
Zero ODP, GWP under 1 GBCSA approved; made in Benoni; ISO 9001:2015 |
Zero ODP; no numeric GWP published |
| Storage on site | All three: store flat, in original packaging, under cover, out of direct sun. Keep away from solvents, VOCs and any naked flame or heat source. | ||
| Certification | Agrément SA × 5 — 2006/323, 2001/287, 2010/382, 2000/277, 2000/276 | Complies SANS 10400-T; NES 713 no Agrément SA certificate held |
Fire test report 2023-02, July 2024 no Agrément SA certificate held |
+ SOURCES FOR THIS SECTION
R-Value by Thickness
| Thickness | ISOboard k 0.026 |
Lambdaboard k 0.024 |
Summit XPS k 0.03 |
|---|---|---|---|
| 25mm | 0.95 | 1.04 | — not made |
| 30mm | 1.14 | 1.25 | 1.00 |
| 40mm | 1.52 | 1.67 | 1.33 |
| 50mm | 1.91 | 2.08 | 1.67 |
| 60mm | 2.29 | 2.50 | 2.00 doubled |
| 70mm | 2.67 | 2.92 | 2.33 special order |
| 80mm | 3.05 | 3.33 | 2.67 doubled |
| 90mm | 3.43 doubled | 3.75 | 3.00 special order |
| 100mm | 3.81 doubled | 4.17 | 3.33 doubled |
+ SOURCES FOR THIS SECTION
Which Thickness for Which Application
| Application | ISOboard | Lambdaboard | Summit XPS |
|---|---|---|---|
| Under surface bed | up to 50mm | up to 50mm | up to 50mm |
| Cavity wall | up to 50mm | up to 50mm | up to 50mm |
| Perimeter wall | up to 50mm | up to 50mm | up to 50mm |
| Nail-up ceiling | up to 50mm | up to 40mm | up to 50mm |
| Under soffit | up to 60mm | up to 60mm | up to 60mm |
| Over rafter / truss | up to 60mm | up to 60mm | up to 60mm |
| Over purlin | up to 100mm | up to 100mm | up to 100mm |
| Inverted roof | up to 100mm | up to 100mm | up to 100mm |
Datasheets & Specifications
Questions Architects Actually Ask
The Other Two Points of View
What the Builder Sees Board sizes and lengths, batten spacing, fixings, purlin spans, and the certificate details that catch people out on site. Site detail
What the Quantity Surveyor Sees How each board is measured and sold, what moves the rate, and how a specification clause lands in a BOQ line. Cost detail
Need Project-Specific Specification Support?
Send through your drawings or schedule of areas and we'll help you spec the right board, thickness and application detail for the project.
Every Question.
Organised. Mostly Sensible.
Everything that didn't fit in the Top 10 lists, sorted by topic instead of by audience — because a good question is a good question, whether you're a homeowner, a builder, or wearing a hard hat with a clipboard.
Stickman note: this page is a helpful guide to SANS 10400-XA:2026, but final compliance must be checked against the official standard, the project drawings, the selected compliance route, and the competent person's project-specific assessment.